A 30 m long tape is standardized at \(25^{\circ}\text{C}\). It was used to measure the length of a line which came out to be 200 m. The temperature during the measurement was \(35^{\circ}\text{C}\). The coefficient of expansion of the tape was \(11 \times 10^{-6}\) per \(^{\circ}\text{C}\). The correction in the measured length (in mm) due to change in temperature is (in integer).